Previous revision
known_issues [2018/09/05 14:01]
jeff Added links to 'wattmons'
known_issues [2019/09/25 10:13]
admin
Line 15: Line 15:
  
 Sometimes browser caches cause graph pages in [[hardware:wattmons|Wattmon]] to show older data.  If you are on a graph page (battery status, energy in Watts) and you are seeing old data, press Ctrl + Shift + R to force reload the page. Sometimes browser caches cause graph pages in [[hardware:wattmons|Wattmon]] to show older data.  If you are on a graph page (battery status, energy in Watts) and you are seeing old data, press Ctrl + Shift + R to force reload the page.
 +===== Temperature Sensor =====
 +
 +In some situations, the Onewire temperature sensor does not give values when over 70 degrees celsius.
 +To solve this, edit /config/onewire.ini and add the line:
 +''presence_pulse_delay=50''
 +Under the ''[general]'' section.  Save and reboot, and it should work.  The default presence pulse delay is 35 uS.
  
 ===== Code issues ===== ===== Code issues =====
 ==== Blank Functions ==== ==== Blank Functions ====
-//Resolved in firmware >= 1.1098 on WattmonPRO and >= 2.1098 on WattmonMEGA//+//Resolved in firmware >= 1.1098 on [[hardware:wattmons:WattmonPRO]] and >= 2.1098 on [[hardware:wattmons:WattmonMEGA]]//
  
 Blank functions cause errors in the [[hardware:wattmons|Wattmon]] parser, with the message ''Invalid } in file ...''.   Blank functions cause errors in the [[hardware:wattmons|Wattmon]] parser, with the message ''Invalid } in file ...''.  