User Tools

Site Tools


known_issues

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
known_issues [2018/09/05 16:09]
jeff Added links to PRO, MINI or MEGA
known_issues [2021/09/13 05:57] (current)
Line 15: Line 15:
  
 Sometimes browser caches cause graph pages in [[hardware:wattmons|Wattmon]] to show older data.  If you are on a graph page (battery status, energy in Watts) and you are seeing old data, press Ctrl + Shift + R to force reload the page. Sometimes browser caches cause graph pages in [[hardware:wattmons|Wattmon]] to show older data.  If you are on a graph page (battery status, energy in Watts) and you are seeing old data, press Ctrl + Shift + R to force reload the page.
 +===== Temperature Sensor =====
 +
 +In some situations, the Onewire temperature sensor does not give values when over 70 degrees celsius.
 +To solve this, edit /config/onewire.ini and add the line:
 +''presence_pulse_delay=50''
 +Under the ''[general]'' section.  Save and reboot, and it should work.  The default presence pulse delay is 35 uS.
  
 ===== Code issues ===== ===== Code issues =====
known_issues.1536163764.txt.gz · Last modified: 2021/09/13 05:56 (external edit)